90 RULAND ROAD:

AVAILABLE Q1 2022

235 pINELAWN ROAD:

AVAILABLE Q3 2022

90 RULAND ROAD:

AVAILABLE Q1 2022

235 pINELAWN ROAD:

AVAILABLE Q3 2022

90_ruland_site_plan.png
235_pinlawn_site_plan.png

TOTAL BUILDING (sf):

 

 

sTRUCTURE:

cOLUMN sPACING:

COLUMN SPACING

AT SPEED BAY:

eXTERIOR:

 

fLOOR cAPACITY:

 

rOOF:

hvac:

 

 

 

ELECTRICAL:

 

FIRE PROTECTION:

 

PLUMBING:

 

 

OFFICE FLOOR TO

CEILING HEIGHT:

 

WAREHOUSE CLEAR

CEILING HEIGHT:

LOADING:

 

 

CONSTRUCTION CLASS:

CAR PARKING:

TRAILER PARKING:

±246,500 SF

Office space can be built up to ±27,160 SF

Additional mezzanine possible

Steel frame, beams, columns, roof, joists

56' x 57'

59' x 57'

 

Pre-cast concrete, insulated load-bearing walls

 

Warehouse/Office: 8" concrete slab (800lb/psf)

Fully adhered EPDM, R=30

Warehouse: Roof-mounted Cambridge units

Office Area (Core & Shell): Multiple electric cooling/gas-fired constant volume rooftop units per tenant requirement

2,500 amps, 277/480 volt service to the building (warehouse)

Warehouse: NFPA-13 2016 Edition Section 8.12-Early

Suppression Fast Response Sprinkler System 6" lateral sanitary connections are provided 2" domestic water service is provided

18'0"

 

 

40'0" to underside of steel at lowest point of roof structure

(51) 9'0" x 10'0" loading docks w/ 35,000lb rated levelers

(2) 12'0" x 16'0" drive-in doors

Group S-1 and B

495

105

TOTAL BUILDING (sf):

 

 

sTRUCTURE:

cOLUMN sPACING:

COLUMN SPACING

AT SPEED BAY:

eXTERIOR:

 

fLOOR cAPACITY:

 

rOOF:

hvac:

 

 

 

ELECTRICAL:

 

FIRE PROTECTION:

 

PLUMBING:

 

 

OFFICE FLOOR TO

CEILING HEIGHT:

 

WAREHOUSE CLEAR

CEILING HEIGHT:

LOADING:

 

 

CONSTRUCTION CLASS:

CAR PARKING:

TRAILER PARKING:

±599,983 SF

Office space can be built up to ±30,758 SF

Additional mezzanine possible

Steel frame, beams, columns, roof, joists

54' x 56'

61' x 63'

 

Pre-cast concrete, insulated load-bearing walls

 

Warehouse/Office: 8" concrete slab (800lb/psf)

Fully adhered EPDM, R=30

Warehouse: Roof-mounted Cambridge units

Office Area (Core & Shell): Multiple electric cooling/gas-fired constant volume rooftop units per tenant requirement

2,500 amps, 277/480 volt service to the building (warehouse)

Warehouse: NFPA-13 2016 Edition Section 8.12-Early

Suppression Fast Response Sprinkler System 6" lateral sanitary connections are provided 2" domestic water service is provided

18'0"

 

 

40'0" to underside of steel at lowest point of roof structure

(120) 9'0" x 10'0" loading docks w/ 35,000lb rated levelers

(2) 12'0" x 16'0" drive-in doors

Group S-1 and B

479

171